TABLE OF CONTENTS

SECTION 1. GENERAL INFORMATION

........................................................................................................... 4

SECTION 2. BEFORE INSTALLATION

............................................................................................................. 4

SECTION 3. FRONT AND BACK FRAME DISASSEMBLY

........................................................................ 5

SECTION 4. BACK FRAME BREAKER CONVERSION

Removing the Electromechanical Trip Devices...................................................................................... 6
Installing the Phase Sensors .................................................................................................................. 7

SECTION 5. FRONT FRAME BREAKER CONVERSION

Installing the Trip Paddle ........................................................................................................................ 8
Installing the Flux Shifter Assembly ....................................................................................................... 9

SECTION 6. BREAKER REASSEMBLY

Frame Assembly................................................................................................................................... 10
Wiring Harness Installation................................................................................................................... 10
Adjusting the Flux Shifter...................................................................................................................... 11
Installing the Trip Unit........................................................................................................................... 12
Configuring the Trip Unit....................................................................................................................... 12

SECTION 7. FOUR-WIRE GROUND FAULT OPTION

................................................................................ 13

SECTION 8. TESTING AND TROUBLESHOOTING

Testing .................................................................................................................................................. 14
Trouble-Shooting .................................................................................................................................. 14

Nuisance Tripping on Ground Fault-Equipped Breakers ........................................................ 14

LIST OF FIGURES

1. Opening springs and old trip devices on an AK-1-50 circuit breaker (view from bottom of

breaker). ........................................................................................................................................................... 5

2.

Crossbar

mechanism pin and retaining clip..................................................................................................... 5

3. EC trip devices before removal. ....................................................................................................................... 6

4. Removal of EC trip devises.............................................................................................................................. 6

5. Parts provided for CT installation per pole....................................................................................................... 7

6. CT post mounted in the breaker back frame. .................................................................................................. 7

7.

CT

installation completed................................................................................................................................. 7

8. Front frame assembly, showing the old trip paddles. ...................................................................................... 8

9.

Installing

the new trip paddle............................................................................................................................ 8

10. Flux shifter assembly and mounting bracket ................................................................................................... 9

11. Flux shifter bracket installed on the front frame (view from underneath with breaker

reassembled). .................................................................................................................................................. 9

12. Flux shifter assembly attached to the mounting bracket.................................................................................. 9

13.

Installing

the

insulating barrier ....................................................................................................................... 10

14. Wiring harness connection to the CTs. .......................................................................................................... 10

15.

Adjusting

the flux shifter ................................................................................................................................. 11

16. Attaching the trip unit to the mounting plate................................................................................................... 12

17. Trip unit mounted onto the breaker................................................................................................................ 12

18.

Neutral

sensor outline for AK-1-50................................................................................................................. 13

19. Cabling diagram for ProTrip™ trip units with ground fault on four-wire loads. .............................................. 16

Advertising