GE Industrial Solutions WattStation Pedestal EVSE Charger Installation User Manual

Page 14

Advertising
background image

WattStation Pedestal Installation Manual

1144

G

GEE EEnneerrggyy

©

©22001122 G

GEE C

Coom

mppaannyy AAllll RRiigghhttss RReesseerrvveedd



SStteepp:: 1166 Open the access door by unlocking
the key on back of the EVSE unit
(Below Top cover assembly)










SStteepp:: 1177 Route the Power wires and Ground
wires as shown in the figure 9


IMPORTANT: WattStation is rated
for 208-240V AC, 30Amps, 1 Phase, 60Hz
power only. The EVSE must be connected
to a centrally grounded system, The ground
conductor should be run with power conductors
and connected to the equipment grounding
lug inside the charger.
Connections to the EVSE are the responsibility
of the installer and purchaser, not GE, and
such connections must comply with
all applicable electrical codes and ordinances.
Torque all the nuts as per the torque
specification in Table 1,
Refer Table 2 for recommended tools.






FFiigguurree -- 88


FFiigguurree -- 99