Ensure that a dedicated circuit, capable of supplying 30A at 208-240 VAC, is available

-

A recommended 40A upstream circuit breaker, located either in a panel board or load center,

should be used.

-

GE WattStation EVSE unit has built in GFCI protection; do not provide any additional GFCI

protection upstream of the EVSE.


7

Torque Specification Table

SSC

CRREEW

W SSIIZZEE

TTO

ORRQ

QU

UEE

TTO

ORRQ

QU

UEE TTO

OLL..

PDB – Power Distribution Block for
Field Wiring

40 in-lb

+/- 2 in-lb

Ground lug

45 in-lb

+/- 2 in-lb

Roller –M5x12, Cup Point set screw

18 in-lb

+/- 2 in-lb

Brush – T-15 Driver size
(Tamperproof Head)

23 in-lb

+/- 2 in-lb

Brush bracket – M5 Hex Head

23 in-lb

+/- 2 in-lb

Bellows bracket top – M5 Philips Head

23 in-lb

+/- 2 in-lb

Bellows bracket bottom – M5 Philips Head

23 in-lb

+/- 2 in-lb

Bellows plate – M3 Nut

18 in-lb

+/- 2 in-lb

Wire trays top – M5 Hex Head

23 in-lb

+/- 2 in-lb

Wire trays bottom– M5 Hex Head

23 in-lb

+/- 2 in-lb

Anchoring bolts – ½” x 6” Hex Head

20 in-lb

+/- 2 in-lb

TTaabbllee 11

W

WaattttSSttaattiioonn sshhoouulldd bbee iinnssttaalllleedd oonnllyy bbyy aa lliicceennsseedd ccoonnttrraaccttoorr,,
aanndd//oorr aa lliicceennsseedd eelleeccttrriicciiaann iinn aaccccoorrddaannccee w

wiitthh aallll aapppplliiccaabbllee

ssttaattee,, llooccaall aanndd nnaattiioonnaall eelleeccttrriiccaall ccooddeess aanndd ssttaannddaarrddss..

WARNING:

Advertising