Drive1 and Drive2 Motor Rotation

If careful attention to phase rotation is not made during connection of the panel to the three-phase power

supply and motor, then there is only a one chance in four that the motor will rotate correctly in both drive1

and drive2 modes.

The other three possibilities and the corresponding corrective actions are as follows:

Problem: Motor turns correctly in Drive2 mode and incorrectly in Drive1 mode.

Solution: Swap the leads at the drive’s output terminals.

Problem: Motor turns correctly in Drive1 mode and incorrectly in Drive2 mode.

Solution: Swap the leads at the drive’s output terminals.

Problem: Motor turns incorrectly in both modes.


Solution: Swap the leads at the motor leads on the contactor's output terminals.


Drive Fault Codes
Refer to FP troubleshooting guide.