GE Industrial Solutions 9-36V ProLynx 5A User Manual

36v prolynx, 5a: non-isolated dc-dc power modules, Data sheet

Advertising
background image

GE

Data Sheet

July 23, 2013

©2012 General Electric Company. All rights reserved.

9-36V ProLynx

TM

5A: Non-Isolated DC-DC Power Modules

9Vdc –36Vdc input; 3Vdc to 18Vdc output; 5A to 2.5A Scaled output current
9Vdc –24Vdc input; -3.3Vdc to -18Vdc output

1

; 5A to 0.7A Scaled output current

Features

Compliant to RoHS EU Directive 2002/95/EC (Z versions)

Compatible in a Pb-free or SnPb reflow environment (Z
versions)

Compliant to IPC-9592 (September 2008), Category 2,
Class II

Extra Wide Input voltage range (9Vdc–36Vdc)

Output voltage programmable from 3Vdc to 18 Vdc via
external resistor

Tunable Loop

TM

to optimize dynamic output voltage

response

Patent Pending AutoLimit

automatic scaling of current

limit with output voltage

Output overcurrent protection (non-latching)

Overtemperature protection

Remote On/Off

Remote Sense

Small size: 20.3 mm x 11.4 mm x 8.5 mm (0.8 in x 0.45 in
x 0.335 in)

Wide operating temperature range [-40°C to

105°C(Ruggedized: -D), 85°C(Regular)]

UL* 60950-1, 2

nd

Ed. Recognized, CSA

C22.2 No.

60950-1-07 Certified, and VDE

(EN60950-1, 2

nd

Ed.)

Licensed

ISO** 9001 and ISO 14001 certified manufacturing
facilities

Applications

Industrial equipment

Distributed power architectures

Intermediate bus voltage applications

Telecommunications equipment

Description

The 9-36V ProLynx

TM

series of power modules are non-isolated dc-dc converters that can deliver up to 5A of output current. These

modules operate over an extra wide range of input voltage (V

IN

= 9Vdc – 36Vdc) and provide a precisely regulated output voltage

from 3Vdc to 18Vdc, programmable via an external resistor. Two new features added with this family of products are the ability to
externally tune the voltage control loop and a variable current limit inversely

dependent

on output voltage. Other features include

remote On/Off, adjustable output voltage, over current and over temperature protection. The Ruggedized version (-D) is capable of
operation up to 105°C and withstand high levels of shock and vibration. The Tunable Loop

TM

, allows the user to optimize the

dynamic response of the converter to match the load with reduced amount of output capacitance leading to savings on cost and
PWB area and AutoLimit enables the module to deliver the max possible output power across the entire voltage range. The 9-36V
ProLynx can also be used for negative output voltage

loads through the use of a specific application schematic


* UL is a registered trademark of Underwriters Laboratories, Inc.

CSA is a registered trademark of Canadian Standards Association.

VDE is a trademark of Verband Deutscher Elektrotechniker e.V.

** ISO is a registered trademark of the International Organization of Standards

1

Output range linked to input voltage range see page 24

RoHS Compliant

Co

VOUT

Vin+

SENSE

Q1

Vout+

TRIM

ON/OFF

Cin

VIN

MODULE

RTUNE

GND

RTrim

CTUNE

R