Data Sheet

9-36V ProLynx

TM

5A: Non-Isolated DC-DC Power Modules

9Vdc –36Vdc input; 3Vdc to 18Vdc output; 5A to 2.5A Scaled output current

9Vdc –24Vdc input; -3.3Vdc to -18Vdc output; 5A to 0.7A Scaled output current

July 23, 2013

©2012 General Electric Company. All rights reserved.

Page 13

Once the unit goes into thermal shutdown it will then wait to
cool before attempting to restart.

Input Undervoltage Lockout

At input voltages below the input undervoltage lockout limit,
the module operation is disabled. The module will begin to
operate at an input voltage above the undervoltage lockout
turn-on threshold.

Output Voltage Programming

The output voltage of the 9-36V ProLynx

TM

module can be

programmed to any voltage from 3Vdc to 18Vdc by
connecting a resistor between the Trim and GND pins of the
module. Certain restrictions apply on the output voltage set
point depending on the input voltage. These are shown in the
Output Voltage vs. Input Voltage Set Point Area plot in Fig. 35.

Without an external resistor between Trim and GND pins, the
output of the module will be 0.7Vdc. To calculate the value of
the trim resistor, Rtrim for a desired output voltage, use the
following equation:

(

)

Ω

=

k

Vo

Rtrim

7

.

0

70

Rtrim is the external resistor in kΩ, and Vo is the desired
output voltage.

Figure 35. Output Voltage vs. Input Voltage Set Point Area

plot showing limits where the output voltage can be set for
different input voltages.

Table 1 provides Rtrim values required for some common
output voltages.

Table 1

V

O, set

(V)

Rtrim (KΩ)

3.3 26.92

5 16.27
6 13.20
9 8.43

12 6.19
15 4.89
18 4.04

By using a ±0.5% tolerance trim resistor with a TC of ±100ppm,
a set point tolerance of ±1.5% can be achieved as specified in

the electrical specification.

Remote Sense

The 9-36V ProLynx

TM

power modules have a Remote Sense

feature to minimize the effects of distribution losses by
regulating the voltage between the VS+ and Vo pin. The

voltage between the VS+ pin and Vo pin should not exceed
0.5V.

V

O

(+)

TRIM

GND

R

trim

LOAD

V

IN

(+)

ON/OFF

VS+

Figure 36. Circuit configuration for programming output
voltage using an external resistor.

Voltage Margining

Output voltage margining can be implemented in the 9-36V
ProLynx

TM

modules by connecting a resistor, R

margin-up

, from the

Trim pin to the ground pin for margining-up the output voltage
and by connecting a resistor, R

margin-down

, from the Trim pin to

output pin for margining-down. Figure 37 shows the circuit
configuration for output voltage margining. The POL
Programming Tool, available at

www.lineagepower.com

under

the Design Tools section, also calculates the values of R

margin-up

and R

margin-down

for a specific output voltage and % margin

Please consult your local GE technical representative for
additional details.

Figure 37. Circuit Configuration for margining Output
voltage

5

10

15

20

25

30

35

40

2

4

6

8

10

12

14

16

18

Input

V

o

lt

a

g

e

(v

)

Output Voltage (V)

Lower Limit

Upper Limit

Vo

MODULE

GND

Trim

Q1

Rtrim

Rmargin-up

Q2

Rmargin-down

Advertising