Output Filtering

The 9-36V ProLynx

TM

modules are designed for low output

ripple voltage and will meet the maximum output ripple
specification with 0.1 µF ceramic and 10 µF ceramic
capacitors at the output of the module. However, additional
output filtering may be required by the system designer for a
number of reasons. First, there may be a need to further

reduce the output ripple and noise of the module. Second, the
dynamic response characteristics may need to be customized
to a particular load step change.

To reduce the output ripple and improve the dynamic
response to a step load change, additional capacitance at the
output can be used. Low ESR polymer and ceramic capacitors

are recommended to improve the dynamic response of the
module. Figures 30 and 31 provide output ripple information

for different external capacitance values at various Vo and for
full load currents. For stable operation of the module, limit the
capacitance to less than the maximum output capacitance as

specified in the electrical specification table. Optimal
performance of the module can be achieved by using the
Tunable Loop

TM

feature described later in this data sheet.

Figure 30. Output ripple voltage for various output voltages
with external 1x10 µF, 2x10 µF or 4x10 µF ceramic

capacitors at the output (max. load). Input voltage is 12V.


Figure 31. Output ripple voltage for various output voltages
with external 1x10 µF, 2x10 µF or 4x10 µF ceramic capacitors
at the output (max. load). Input voltage is 28V.

Safety Considerations

For safety agency approval the power module must be
installed in compliance with the spacing and separation
requirements of the end-use safety agency standards, i.e., UL
60950-1 2nd, CSA C22.2 No. 60950-1-07, DIN EN 60950-1:2006
+ A11 (VDE0805 Teil 1 + A11):2009-11; EN 60950-1:2006 +

A11:2009-03.
For the converter output to be considered meeting the
requirements of safety extra-low voltage (SELV), the input must
meet SELV requirements. The power module has extra-low
voltage (ELV) outputs when all inputs are ELV.
The input to these units is to be provided with a fast-acting
fuse with a maximum rating of 8A in the positive input lead

.

10

20

30

40

50

3

4

5

6

7

8

Ri

ppl

e

(mV

p-p

)

Output Voltage(Volts)

1x10uF

2x10uF

4x10uF

10

30

50

70

90

110

130

150

170

2

4

6

8

10

12

14

16

18

Ri

pp

le

(m

V

p

-p

)

Output Voltage(Volts)

1x10uF

2x10uF

4x10uF