36v prolynx, 5a: non-isolated dc-dc power modules, Data sheet – GE Industrial Solutions 9-36V ProLynx 5A User Manual

Page 21: Surface mount information

Advertising
background image

GE

Data Sheet

9-36V ProLynx

TM

5A: Non-Isolated DC-DC Power Modules

9Vdc –36Vdc input; 3Vdc to 18Vdc output; 5A to 2.5A Scaled output current

9Vdc –24Vdc input; -3.3Vdc to -18Vdc output; 5A to 0.7A Scaled output current

July 23, 2013

©2012 General Electric Company. All rights reserved.

Page 21

Surface Mount Information

Pick and Place

The 9-36V ProLynx

TM

modules use an open frame

construction and are designed for a fully automated
assembly process. The modules are fitted with a label
designed to provide a large surface area for pick and place

operations. The label meets all the requirements for surface
mount processing, as well as safety standards, and is able to
withstand reflow temperatures of up to 300

o

C. The label also

carries product information such as product code, serial
number and the location of manufacture.

Nozzle Recommendations

The module weight has been kept to a minimum by using
open frame construction. Variables such as nozzle size, tip
style, vacuum pressure and placement speed should be
considered to optimize this process. The minimum
recommended inside nozzle diameter for reliable operation is
3mm. The maximum nozzle outer diameter, which will safely
fit within the allowable component spacing, is 7 mm.

Bottom Side / First Side Assembly

This module is not recommended for assembly on the bottom
side of a customer board. If such an assembly is attempted,
components may fall off the module during the second reflow
process.

Lead Free Soldering

The 9-36V ProLynx

TM

modules are lead-free (Pb-free) and

RoHS compliant and fully compatible in a Pb-free soldering
process. Failure to observe the instructions below may result

in the failure of or cause damage to the modules and can
adversely affect long-term reliability.

Pb-free Reflow Profile

Power Systems will comply with J-STD-020 Rev. C
(Moisture/Reflow Sensitivity Classification for Nonhermetic

Solid State Surface Mount Devices) for both Pb-free solder
profiles and MSL classification procedures. This standard
provides a recommended forced-air-convection reflow profile

based on the volume and thickness of the package (table 4-2).
The suggested Pb-free solder paste is Sn/Ag/Cu (SAC). The

recommended linear reflow profile using Sn/Ag/Cu solder is
shown in Fig. 41.

Soldering outside of the recommended

profile requires testing to verify results and performance.

For questions regarding Land grid array(LGA) soldering, solder
volume; please contact GE for special manufacturing process
instructions.

MSL Rating

The 9-36V ProLynx

TM

modules have a MSL rating of 2a.

Storage and Handling

The recommended storage environment and handling

procedures for moisture-sensitive surface mount packages is
detailed in J-STD-033 Rev. A (Handling, Packing, Shipping and

Use of Moisture/Reflow Sensitive Surface Mount Devices).
Moisture barrier bags (MBB) with desiccant are required for
MSL ratings of 2 or greater. These sealed packages should not

be broken until time of use. Once the original package is
broken, the floor life of the product at conditions of

≤ 30°C and

60% relative humidity varies according to the MSL rating (see
J-STD-033A). The shelf life for dry packed SMT packages will

be a minimum of 12 months from the bag seal date, when
stored at the following conditions: < 40° C, < 90% relative

humidity.

Figure 41. Recommended linear reflow profile using
Sn/Ag/Cu solder.

Post Solder Cleaning and Drying Considerations

Post solder cleaning is usually the final circuit-board assembly

process prior to electrical board testing. The result of
inadequate cleaning and drying can affect both the reliability

of a power module and the testability of the finished
circuit-board assembly. For guidance on appropriate soldering,
cleaning and drying procedures, refer to Board Mounted Power

Modules: Soldering and Cleaning Application Note (AN04-001).







Per J-STD-020 Rev. C

0

50

100

150

200

250

300

Reflow Time (Seconds)

R

efl

ow

T

em

p

C

)

Heating Zone
1°C/Second

Peak Temp 260°C

* Min. Time Above 235°C
15 Seconds

*Time Above 217°C

60 Seconds

Cooling
Zone

Advertising