3.2.1.6.1.2 Write drive parameter - Reply OK

If the Drive parameter is written correctly, the response is:

DATA TYPE

FIELD

VALUE

MEANING

Byte

Service Code 33hex OR 80hex

Set Drive Parameter

Reply code- Object

Specific Service.

Word

Result

0000

Result field equal to zero

means writing correctly

executed.

dn365

3.2.1.6.1.3 Write drive parameter - Reply Error

If the writing of the drive parameter has been rejected, the response is the
following:

DATA TYPE

FIELD

VALUE

MEANING

Byte

Service Code 33hex OR 80hex

Set Drive Parameter

Reply code- Object

Specific Service.

Word

Result

XXXX

1

Drive specific error code.

dn370

1) For error codes see chapter 6.0

3.2.1.6.2 Read Drive Parameter

In this example is shown the reading of a Drive parameter; the cases of positive
or wrong reading are distinguished.

3.2.1.6.2.1 Read Drive Parameter Request

The data frame for the Drive parameter reading is composed as follows:

DATA

TYPE

FIELD

VALUE

MEANING

Byte

Service

Code

32hex

Get Drive Parameter -

Object Specific Service.

See Note

1)

Class ID

66hex

Drive Parameter Access

Class Object.

See Note

1)

Instance

ID

XXXX

Drive Parameter Index in

format Lowbyte-High

byte.

dn375

1) Byte or Word depending on the type of allocation executed by the Master.