6KCV301DNET

23

——————

Interface card DeviceNet

——————

3.2.2.6.2.2 Read DGF parameter - Reply OK

If the DGF-parameter is read correctly, the response is:

DATA TYPE

FIELD

VALUE

MEANING

Byte

Service

Code

32hex OR

80hex

Get DGF Parameter

Reply code- Object

Specific Service.

Word

Result

0000

Result field equal to zero

means reading correctly

executed.

Data Type

1)

XX

DGF specific data type

code.

N/U

00

Not used; has to be set to

zero.

XX

Low byte-Low word DGF

parameter value.

XX

High byte-Low word DGF

parameter value.

XX

Low byte-High word DGF

parameter value.

XX

High byte-High word

DGF parameter value.

dn3985ge

Byte

VALUE

1) For data-type codes see DGF-manual.

3.2.2.6.2.3 Read DGF parameter - Reply Error

If the reading of the DGF-parameter is rejected, the response is the following:

DATA TYPE

FIELD

VALUE

MEANING

Byte

Service

Code

32hex OR

80hex

Get DGF Parameter

Reply code- Object

Specific Service

Word

Result

XXXX

1)

DGF specific error code

dn3990ge

1) For error codes see DGF-manual.