Figure 4-2: home position on the ole panel, Installation guidelines and procedures, continued – GE Industrial Solutions Off Line Equalization (OLE) User Manual
Page 21
Off Line Equalization Panel and Converter for GPS4848/GPS4812
Issue 4 January 2008
Converter Installation 4 - 3
Installation Guidelines and Procedures, continued
Installing the ES671 Converter, continued
Step
Action
4
Ensure that the Converter output connector on the
ED83143-30 panel is in the Home Position. See Figure
4-2.
Retaining
Screw
Converter
Converter Output Connector
In Home Position
Figure 4-2: Home Position on the OLE Panel
5
Push converter firmly into the slot, ensuring that the
bottom of the converter is aligned in the plastic rail in the
slot.
6
Screw in the retaining screw at the bottom of the
converter front panel.
7
Plug the interface connector
into the socket on the front
of the converter, ensuring
full insertion and latching.
Equalize
Current
Output
Adjust
On –
Standby
Alarm
Socket for
Interface
Connector