Leds, Jumpers, Leds 5. jumpers – GE Industrial Solutions 6KCV301ENC User Manual
Page 11
11
Digital Encoder Input Expansion and Encoder Repeater
6KCV301ENC
4. LEDs
+5V ________________________ The led is lit when internal +5V power supply is
available from the Drive.
5ENC ______________________ The led is lit when +5V power supply is provided by
XSI terminal.
24ENC _____________________ The led is lit when +15÷24V power supply is provided
by XSI terminal.
+5VE _______________________ The led is lit when power supply for driver encoder
repeater TTL (+5V) is provided.
DRV _______________________ The led is lit when power supply for driver encoder
repeater TTL (+15÷24V) is provided.
5. JUMPERS
Name
Default
S1 and S2 Setting divider for encoder repeater (see table below) OFF, OFF
ON 0 Channel included in the encoder loss logic
OFF 0 Channel not included in the encoder loss logic
exp2F70
Description
S7
OFF
Set Jumper to ON when encoder loss detection is used also for zero channel.
(Alarm active only if a digital encoder with all A, Anot, B, Bnot channels and
+15V/24V power supply is used)
Encoder divider
Jumper S1
Jumper S2
/1
OFF
OFF
/2
OFF
ON
/4
ON
OFF
/8
ON
ON
exp2F80
DIVIDER FOR ENCODER REPEATER SELECTION