background image

11

———— Digital Encoder Input Expansion and Encoder Repeater ————

6KCV301ENC

4. LEDs

+5V ________________________ The led is lit when internal +5V power supply is

available from the Drive.

5ENC ______________________ The led is lit when +5V power supply is provided by

XSI terminal.

24ENC _____________________ The led is lit when +15÷24V power supply is provided

by XSI terminal.

+5VE _______________________ The led is lit when power supply for driver encoder

repeater TTL (+5V) is provided.

DRV _______________________ The led is lit when power supply for driver encoder

repeater TTL (+15÷24V) is provided.

5. JUMPERS

Name

Default

S1 and S2 Setting divider for encoder repeater (see table below) OFF, OFF

ON 0 Channel included in the encoder loss logic
OFF 0 Channel not included in the encoder loss logic

exp2F70

Description

S7

OFF

Set Jumper to ON when encoder loss detection is used also for zero channel.
(Alarm active only if a digital encoder with all A, Anot, B, Bnot channels and
+15V/24V power supply is used)

Encoder divider

Jumper S1

Jumper S2

/1

OFF

OFF

/2

OFF

ON

/4

ON

OFF

/8

ON

ON

exp2F80

DIVIDER FOR ENCODER REPEATER SELECTION

Advertising