(continued)

The following figures provide typical characteristics for the JRW070A0M (1.5V, 70A) at 25ºC. The figures are identical
for either positive or negative Remote On/Off logic.

INP

UT

CURRE

N

T

,(

A

)

0

0.5

1

1.5

2

2.5

3

3.5

4

25

35

45

55

65

75

I

o

= 0 A

I

o

= 35 A

I

o

= 70 A

O

N

/O

F

F

V

OL

T

A

GE

O

U

T

P

U

T

V

O

L

T

A

G

E

V

O

n/

of

f

(V

) (5

V

/d

iv

)

V

O

(V

) (0

.5

V

/d

iv

)

INPUT VOLTAGE, V

IN

(V)

TIME, t (1ms/div)

Figure 31. Typical Start-Up (Input Current)
characteristics at room temperature.

Figure 34. Typical Start-Up Characteristics from
Remote ON/OFF.

EF

F

IC

IEN

C

Y (

%

)

70

72

74

76

78

80

82

84

86

88

90

0

10

20

30

40

50

60

70

V

i

= 36 V

V

i

= 48 V

V

i

= 75 V

O

U

T

P

UT

CURRE

N

T

O

UT

P

U

T

V

O

L

T

A

G

E

I

O

,

(A

) (

1

0

A

/d

iv

)

V

O

(V

)

(1

0

0

mV

/d

iv

)

OUTPUT CURRENT, I

o

(A)

TIME, t (200

µs/div)

Figure 32. Converter Efficiency Vs Load at Room
temperature.

Figure 35. Transient Response to Dynamic Load
Change from 50% to 25% of full load current.

OU

T

P

U

T

V

OL

T

A

GE

V

O

(V

) (2

0

m

V

/d

iv

)

O

U

T

PU

T

C

U

R

R

EN

T

O

U

T

PU

T

VO

L

T

AG

E

I

O

,

(A

) (

1

0

A

/d

iv

)

V

O

(V

)

(1

0

0

mV

/d

iv

)

TIME, t (1

µs/div)

TIME, t (200

µs/div)

Figure 33. Typical Output Ripple and Noise at Room
temperature and
I

o

= I

o,max

.

Figure 36. Transient Response to Dynamic Load
Change from 25% to 50 % of full load current.

75 Vin

48 Vin

36 Vin

Advertising