Absolute maximum ratings, Electrical specifications – GE Industrial Solutions JRW017-040-060-065-070 Series User Manual

Page 2

Advertising
background image

Data Sheet

June 14, 2010

JRW017-070 Series Power Modules DC-DC Converters

36-75Vdc Input; 1.2Vdc to 12Vdc Output

LINEAGE

POWER

2

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.

Parameter

Device

Symbol

Min

Max

Unit

Input Voltage

Continuous

All

V

IN

-0.3

80

Vdc

Transient (100 ms)

V

IN, trans

-0.3

100

Vdc

Operating Ambient Temperature

All

T

A

-40

85

°C

(see Thermal Considerations section)

Storage Temperature

All

T

stg

-55

125

°C

I/O Isolation

All

1500

Vdc

Electrical Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Operating Input Voltage

All

V

IN

36

48

75

Vdc

Maximum Input Current

(V

IN

=0 to 75V , I

O

=I

O, max

)

All

I

IN,max

7

Adc

Inrush Transient

All

I

2

t

1

A

2

s

Input Reflected Ripple Current, peak-to-peak

(5Hz to 20MHz, 12μH source impedance; V

IN

=0V

to 75V, I

O

= I

Omax

; see Figure 31)

All

-

15

-

mAp-p

Input Ripple Rejection (120Hz)

All

60

dB

CAUTION: This power module is not internally fused. An input line fuse must always be used.

This power module can be used in a wide variety of applications, ranging from simple standalone operation to an
integrated part of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included;
however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies
require a time-delay fuse with a maximum rating of 20A (see Safety Considerations section). Based on the
information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a
lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information.

Advertising