Data Sheet

June 14, 2010

JRW017-070 Series Power Modules DC-DC Converters

36-75Vdc Input; 1.2Vdc to 12Vdc Output

LINEAGE

POWER

4

Electrical Specifications

(continued)

Parameter

Device

Symbol

Min

Typ

Max

Unit

Efficiency

P

η

84

%

(V

IN

=V

IN,nom

, I

O

=I

O, max

, V

O

= V

O,set

T

A

=25°C)

M

86

%

Y

87

%

G

90

%

F

91

%

A

92

%

B

92

%

Switching Frequency

f

sw

300

kHz

Dynamic Load Response

(

∆Io/∆t=1A/10µs; V

in

=V

in

,nom; T

A

=25°C;

Tested with a 10 μF aluminum and a 1.0

μF tantalum capacitor across the load.)

Load Change from Io= 50% to 75% of
Io,max:

Peak Deviation

P,M,Y,G

V

pk

6

%V

O, set

Settling Time (Vo<10% peak deviation)

t

s

300

µs

F,A

V

pk

4

%V

O, set

t

s

300

µs

B

V

pk

3

%V

O, set

t

s

500

µs

Load Change from Io= 75% to 50% of
Io,max:

Peak Deviation

P,M,Y,G

V

pk

6

%V

O, set

Settling Time (Vo<10% peak deviation)

t

s

300

µs

F,A

V

pk

4

%V

O, set

t

s

300

µs

B

V

pk

3

%V

O, set

t

s

500

µs

Isolation Specifications

Parameter

Symbol

Min

Typ

Max

Unit

Isolation Capacitance

C

ISO

2700

pF

Isolation Resistance

R

ISO

10

General Specifications

Parameter

Min

Typ

Max

Unit

Calculated MTBF (I

O

= 80% of I

O, max

, T

A

=40°C,

airflow=1m/s

(400LFM)

1,363,000

Hours

Weight

60.3 (2.1)

g (oz.)

Advertising