JRW017-070 Series Power Modules DC-DC Converters
36-75Vdc Input; 1.2Vdc to 12Vdc Output
LINEAGE
POWER
17
Feature Descriptions
(continued)
Output Voltage Programming
(continued)
Examples:
To trim down the output of a nominal 3.3V module
(JRW060A0F) to 3.1V
100
3
.
3
1
.
3
3
.
3
%
×
−
=
∆
V
V
V
∆% = 6.06
Ω
−
=
−
K
R
down
adj
2
06
.
6
100
R
adj-down
= 14.5 k
Ω
To trim up the output of a nominal 3.3V module
(JRW060A0F) to 3.6V
100
3
.
3
3
.
3
6
.
3
%
×
−
=
∆
V
V
V
Δ% = 9.1
(
)
Ω
+
−
+
=
−
K
R
up
adj
1
.
9
)
1
.
9
*
2
100
(
1
.
9
*
225
.
1
1
.
9
100
*
3
.
3
R
tadj-up
= 19.3 k
Ω