Radj-down = 14.5 k – GE Industrial Solutions JRW017-040-060-065-070 Series User Manual

Page 17

Advertising
background image

Data Sheet

June 14, 2010

JRW017-070 Series Power Modules DC-DC Converters

36-75Vdc Input; 1.2Vdc to 12Vdc Output

LINEAGE

POWER

17

Feature Descriptions

(continued)

Output Voltage Programming

(continued)

Examples:

To trim down the output of a nominal 3.3V module
(JRW060A0F) to 3.1V

100

3

.

3

1

.

3

3

.

3

%

×

=

V

V

V

∆% = 6.06

=

K

R

down

adj

2

06

.

6

100

R

adj-down

= 14.5 k

To trim up the output of a nominal 3.3V module
(JRW060A0F) to 3.6V

100

3

.

3

3

.

3

6

.

3

%

×

=

V

V

V

Δ% = 9.1

(

)

+

+

=

K

R

up

adj

1

.

9

)

1

.

9

*

2

100

(

1

.

9

*

225

.

1

1

.

9

100

*

3

.

3

R

tadj-up

= 19.3 k

Advertising