97

Specific problems and corrective

actions

Listed below are specific problems that may arise during the use of
your server and their possible solutions.

Power indicator does not light.

Do the following:

Make sure the power supply module is properly installed.

Make sure the power cord is connected correctly.

Make sure that the wall outlet has power. Test it by plugging in
another device.

Make sure the power indicator on the front panel is lit up.

Remove all add-in cards and see if the system boots.
If reboot is successful, install the cards back in one at a time with a
reboot between each addition to determine if one of them is
causing the problem.

Make sure that you have properly installed system compliant
memory modules, and that they are populated according to the
system guidelines.

Make sure that you have installed system compliant processors,
and that they are populated according to the system guidelines.

HDD activity indicator does not light.

Do the following:

Make sure the drive is not disabled in the BIOS Setup Utility.

Make sure the drive is compatible

Make sure you have not exceeded the power budget for the
server.

Check that relevant switches and jumpers on the hard drive and on
the backplane board are set correctly.