ME Subsystem Configuration

System Acoustic & Performance Configuration

Parameter

Description

Options

ME-HECI
Support

Select Enabled to enable ME-HECI (Host
Embedded Controller Interface) support,
which will allow the Host OS to
communicate directly with the
Management Engine (ME) in a standard
method for system management,
effectively replacing the SMbus.

Enabled
Disabled

Parameter

Description

Options

Throttling -
Closed Loop

Throttling improves reliability and
reduces power consumption in the
processor by automatic voltage control
during processor idle states.

Enabled
Disabled

Hysteresis

Temperature
(Available
when Closed
Loop is
enabled.)

Temperature Hysteresis is the
temperature lag (in degrees Celsius)
after the predefi ned DIMM
temperature threshold is reached before
Closed Loop Throttling begins.

Disabled
1.5

o

C

3.0

o

C

6.0

o

C

Guardband

Temperature
(Available
when Closed
Loop is
enabled.)

This is the temperature that applies to the DIMM
temperature threshold. Each step is in 0.5

o

C increments.

The default is [006]. Press <+> or <-> on your keyboard to
change this value.

Inlet

Temperature

This is the temperature detected at the chassis inlet. Each
step is in 0.5

o

C increments. The default is [070].

Temperature

Rise

This is the temperature rise to the DIMM thermal zone.
Each step is in 0.5

o

C increments. The default is [020].

Air Flow

This is the air fl ow speed to the DIMM modules. Each step
is one mm/sec. The default is [1500].