John Wood Envirosense Power Vent User Manual

Page 16

Advertising
background image

16

vent pIpe terMInatIon

The first step is to determine where the vent pipe will terminate.

See Figures 15, 20 and 21. The vent may terminate through a

sidewall as shown in Figure 20 or through the roof as shown in

Figure 21.

The vent system must terminate so that proper clearances are

maintained as cited in local codes or the current edition of the Natural

Gas and Propane Installation Code (CAN/CSA-B149.1).

Instructions on proper installation through a sidewall are provided

in Figure 15.
Plan the vent system layout so that proper clearances are maintained

from plumbing and wiring.
Vent pipes serving power vented appliances are classified by building

codes as “vent connectors”. Required clearances from combustible

materials must be provided in accordance with information in

this manual under LOCATING THE NEW WATER HEATER and

INSTALLING THE WATER HEATER, and with the National Fuel

Gas Code and local codes.

fIGure 15

canadIan horIZontal vent clearances