Installing the new water heater – John Wood Envirosense Power Direct Vent (prior to May 2010) User Manual

Page 12

Advertising
background image

12

closed water sYsteMs

Water supply systems may, because of code requirements or such

conditions as high line pressure, among others, have installed devices

such as pressure reducing valves, check valves, and back flow preventers.

Devices such as these cause the water system to be a closed system.

therMal eXpansIon

As water is heated, it expands (thermal expansion). In a closed system

the volume of water will grow when it is heated. As the volume of water

grows there will be a corresponding increase in water pressure due

to thermal expansion. Thermal expansion can cause premature tank

failure (leakage). This type of failure is not covered under the limited

warranty. Thermal expansion can also cause intermittent temperature-

pressure relief valve operation: water discharged from the valve due to

excessive pressure build up. This condition is not covered under the

limited warranty. The temperature-pressure relief valve is not intended

for the constant relief of thermal expansion.

A properly sized thermal expansion tank should be installed

on all closed systems to control the harmful effects of thermal

expansion..

fIGure 10.

note: to protect against untimely corrosion of hot and cold

water fittings, it is strongly recommended that di-electric unions

or couplings be installed on this water heater when connected

to copper pipe, see figure 2 also.

cheMIcal vapor corrosIon

CORROSION OF THE FLUEWAYS AND VENT SYSTEM MAY OCCUR IF

AIR FOR COMBUSTION CONTAINS CERTAIN CHEMICAL VAPORS. SUCH

CORROSION MAY RESULT IN FAILURE AND RISK OF ASPHYXIATION.
Spray can propellants, cleaning solvents, refrigerator and air

conditioning refrigerants, swimming pool chemicals, calcium and

sodium chloride (water softener salt), waxes, and process chemicals

are typical compounds which are potentially corrosive.
Do not store products of this sort near the heater. Also, air which is

brought in contact with the heater should not contain any of these

chemicals. If necessary, uncontaminated air should be obtained from

remote or outside sources. The limited warranty is voided when failure

of water heater is due to a corrosive atmosphere. (See limited warranty

for complete terms and conditions).

water pIpInG

HOTTER WATER CAN SCALD:

Water heaters are intended to produce hot water. Water heated to a

temperature which will satisfy space heating, clothes washing, dish

washing, cleaning and other sanitizing needs can scald and permanently

injure you upon contact. Some people are more likely to be permanently

injured by hot water than others. These include the elderly, children, the

physically or developmentally disabled. If anyone using hot water fits into

one of these groups or if there is a local code or state law requiring a

certain temperature water at the hot water tap, then you must take special

precautions. In addition to using the lowest possible temperature setting

that satisfies your hot water needs, a means such as a *mixing valve

should be used at the hot water taps used by these people or at the water

heater, see Figure 2. Valves for reducing point of use temperature by

mixing cold and hot water are also available:
Consult a Qualified Installer or Service Agency. Follow manufacturer’s

instructions for installation of the valves. Before changing the factory

setting on the thermostat, read the “Temperature Regulation” section in

this manual.

This water heater shall not be connected to any heating systems or

component(s) used with a non-potable water heating appliance.
All piping components connected to this unit for space heating

applications shall be suitable for use with potable water.
Toxic chemicals, such as those used for boiler treatment shall not be

introduced into this system.
When the system requires water for space heating at temperatures higher

than required for domestic water purposes, a tempering valve must be

installed. Please refer to Figure 2 for suggested piping arrangement.

InstallInG the new water heater

Advertising