John Wood Envirosense Power Direct Vent (prior to May 2010) User Manual

Page 22

Advertising
background image

22

This concentric vent termination kit may be used with 3 or 4 inch diameter

pipe systems. When connecting to a 4 in. diameter pipe system a 3 x 4

inch field supplied reducer is to be installed at the intake and exhaust

connection of the concentric vent termination kit.

safetY consIderatIons

Installing and servicing water heating equipment can be hazardous due to

gas and electrical components. Installation and service of the concentric

vent termination requires ability equivalent to that of a qualified installer or

service agent, see page 2. All precautions in the literature, on tags, and

labels attached to the unit must be observed.

Follow all safety codes. Wear safety glasses and work gloves.

fIGure 24.

fIGure 25.

* dimension 21 1/8 in. may be lengthened to 60 in. maximum.

dimension 21 1/8 in. may also be shortened by cutting the

pipes, provided in the kit, to 12 in. minimum.
** dimension 39 will change accordingly as dimension

21 1/8 in. is lengthened or shortened.

fIGure 26.

InstallatIon procedure 1 roof terMInatIon,

see figure 26.

1. Determine best location for termination kit.

note: roof termination is preferred since it is less

susceptible to damage, has reduced chances to intake

contaminants, and less visible vent vapors.
2. Cut 1 hole (5 in. diameter)

3. Partially assemble concentric vent termination kit.

a) Cement Y concentric fitting to larger diameter kit

pipe, see Figure A.

b) Cement rain cap to smaller diameter kit pipe, see Figure A.

fIGure 27.

note: Instead of cementing the smaller pipe to the rain cap, a

field-supplied stainless steel screw may be used to secure the

2 components together when field disassembly is desired for

cleaning, see figure 27.

warnInG

when using alternate screw method, drill clearance hole in rain

cap and pilot hole in vent pipe for screw size being used. failure

to drill adequate holes may cause cracking of pvc components,

allowing combustion products to be recirculated. failure to

follow this warning could result in personal injury or death.

warnInG

do not operate the heater with rain cap removed or recirculation

of combustion products may occur. water may also collect inside

larger combustion-air pipe and flow to the burner enclosure.

failure to follow this warning could result in product damage or

improper operation, personal injury or death.

4. Install Y concentric fitting and pipe assembly through

structure’s hole and field supplied roof boot/flashing.

fIGure 28.

note: do not allow insulation or other materials to accumulate

inside pipe assembly when installing through hole.

Advertising