Caution – John Wood Noritz Concentric Vent - NR98-DVC (N-0751M) User Manual

Page 9

Advertising
background image

9

Illustration

Check

6. Drill holes for the remaining four screws.

7. Hang the unit again by the first screw, and then

insert and tighten the remaining four screws.

8. Take waterproofing measures so that water does

not enter the building from screws mounting the
device.

• Make sure the unit is installed securely so that it will

not fall or move due to vibrations or earthquakes.

• The weight of the device will be applied to the wall. If the strength of the wall is not suffi-

cient, reinforcement must be done to prevent the transfer of vibration.

• Do not drop or apply unnecessary force to the device when installing. Internal parts may

be damaged and may become highly dangerous.

• Install the unit on a vertical wall and ensure that it is level.

Locating Screw Holes

Mounting

Structure

• When installing with bare hands, take caution to

not inflict injury.

• Be careful not to hit electrical wiring, gas, or water

piping while drilling holes.

Item

CAUTION

Be sure to do

Installations at Elevations

Above 610m (2,000').

• If this water heater is being installed at an elevation of 610m

(2,000') or higher, disconnect the connector labeled "High
Elevation Disconnect" as illustrated on the right. This con-
nector is located inside the unit.

HIGH ELEV

ATION

DISCONNECT

• Disconnect power to the Water Heater before disconnecting

this connector. Failure to perform this step will result in a
"73" code displayed on the Remote Controller and a cease in
operation. If this occurs, disconnect, then reconnect power
to the Water Heater to reset the system.

Mounting Bracket
(upper)

Location of Screw Hole

Locating Screw Holes

10 - 46mm
(0.4 - 1.8")

mounting bracket
(upper)

mounting bracket
(lower)

mark
(10mm (0.4") intervals)

Tapping Screw

• The distance between the unit and the wall can be ad-

justed within the range of 10 - 46mm (0.4 - 1.8").
Adjust the brackets as necessary to accommodate the
vent system (factory default is 10mm (0.4")).

1. Loosen the four screws in the mounting bracket (upper),

match the desired mark to the back of the unit, and then
tighten the screws.

2. Loosen the four screws in the mounting bracket (lower) and

secure it in the same position as the upper mounting bracket.

3. Drill a single screw hole, making sure to hit a stud.

4. Insert and tighten the screw and hang the unit by

the upper wall mounting bracket.

5. Determine the positions for the remaining four screws

(two for the top bracket and two for the bottom), and
remove the unit.

Advertising