Remote contr ol, cont’d – Extron Electronics MAV Plus series Large Scale Setup Guide User Manual

Page 16

Advertising
background image

Cr

ossPoint / MA

V Matrix Switchers • Remote Contr

ol

Remote Contr

ol, cont’d

4-6

Cr

ossPoint / MA

V Matrix Switchers • Remote Contr

ol

4-7

Refer also to the

Cr

ossPoint 450 Plus / MA

V Plus User’

s Manual

at

www

.extron.com

.

Refer also to the

Cr

ossPoint 450 Plus / MA

V Plus User’

s Manual

at

www

.extron.com

.

Command

ASCII command

(host to switcher)

Response

(switcher to host)

Additional description

Audio output volume

Set the audio volume to a specific
value

X@

*

X%

V

Out

X@

•Vol

X%]

Example:

1*50v

Out01•Vol50

]

Set output 1 volume to an

X%

value of 50, an

attenuation of 14 dB (79% of total volume).

Increment volume

X@

+V

Out

X@

•Vol

X%]

Increase volume by 1 step.

Example:

1+V

Out01•Vol51

]

Decrement volume

X@

-V

Out

X@

•Vol

X%]

Decrease volume by 1 step.

Read output volume

X@

V

X%]

Save and recall presets

N

• If you try to recall a preset that is not saved, the matrix switcher responds with the error code

E11.

The following characters are invalid in preset names: + - , ` @ = [ ] { } ‘ “ ; : | \ and ?.

Save current configuration as a
global preset

X^,

Spr

X^]

Command character is a comma.

Example:

9

,

Spr09

]

Save current ties as preset 9.

Recall a global preset

X^.

Rpr

X^]

Command character is a period.

Example:

5

.

Rpr05

]

Recall preset 5, which becomes the current
configuration.

Command

ASCII command

(host to switcher)

Response

(switcher to host)

Additional description

Lock (executive) modes

N

See “Setting the front panel locks (Executive modes)” on page 3-4 for more information on the

Lock modes.

Lock all front panel functions

1X

Exe1

]

Enable Lock mode 1.

Lock advanced front panel functions

2X

Exe2

]

Enable Lock mode 2.

Unlock all front panel functions

0X

Exe0

]

Enable Lock mode 0.

View lock status

X

X&]

N

X&

= Lock mode

0, 1, or 2

N

X@

= Output number

01 – (maximum number of outputs for your model)

X%

= Volume

0 – 64 (1 dB/step except for 0-to-1, which is 22 dB) (default = 64 [0 dB])

X^

= Preset number

00 - 64 (00 = current configuration, for viewing only)

Advertising