CrossPoint / MAV Matrix Switchers • Remote Control

Remote Control, cont’d

4-12

CrossPoint / MAV Matrix Switchers • Remote Control

4-13

Refer also to the CrossPoint 450 Plus / MAV Plus User’s Manual at

www.extron.com

.

Refer also to the CrossPoint 450 Plus / MAV Plus User’s Manual at

www.extron.com

.

3

.

If you selected IP [LAN] in step 2

, the IP Connection

window appears.

a

. Examine the Matrix IP Address field, which displays

the last Matrix IP address entered.

If necessary

, enter the correct IP address in the field.

N

192.168.254.254 is the factory-specified default value for

this field.

b

. If the switcher is password protected, enter the

appropriate administrator or user password in the

Password field.

c

. Click Connect. The Matrix Switchers Control Program

is ready for operation.

Accessing the HTML Pages

Another way to operate the switcher is via its factory-installed

HTML pages, which are always available and cannot be erased

or overwritten. The switcher’s HTML pages are accessible

through its LAN port, connected via a LAN or WAN, using a

web browser such as Microsoft Internet Explorer. See

h

on

page 2-5, for connection information.

Configuring for Network Communication

The first time you connect a PC to a switcher BME via its LAN

port, you may need to temporarily change the PC’s IP settings

in order to communicate with the controller. Then you must

change the controller’s default settings (IP address, subnet

mask, and [optional] administrator name and password) in

order to use the unit on an intranet (LAN) or on the Internet.

After you have set up the CrossPoint or MAV switcher BME for

network communication, you can reset the PC to its original

network configuration.

N

The computer and the switcher BME must both be

connected to the same subnet on a LAN (using a straight-

through cable). Alternatively, you can use a crossover

Ethernet cable to connect the controller directly to the

computer.

Use the ARP command to configure the IP address as follows:
1

.

Obtain a valid IP address for the CrossPoint or MAV

switcher BME from the network administrator.

2

.

Obtain the switcher BME’s MAC address (UID #) from the

label on its rear panel. The MAC address should have this

format: 00-05-A6-xx-xx-xx.

3

.

If the switcher BME has never been configured and is

still set for factory defaults, go to step 4. If not, perform

a Mode 4 system reset. For detailed information

on reset modes, see “Rear Panel Operations” in the

CrossPoint 450 Plus / MAV Plus Switcher User's Manual

.

N

The switcher BME must be configured with the factory

default IP address (192.168.254.254) before the ARP

command is executed, as described below.

4

.

At the PC, access the MS-DOS command prompt, then

enter the

arp –s command. Type in the desired new

IP address for the unit (obtained in step 1) and the unit’s

MAC address (from the unit's rear panel). For example:

arp –s 10.13.197.7 00-05-A6-03-69-B0 and then

press {Enter}.

N

If you connect to the switcher via the LAN port, and it is the

first time you have done so, you may change the controller’s

default settings (IP address, subnet mask, and [optional]

administrator name and password). See " Configuring for Network

Communication" for details.