Remote control connections, Bme connection and selection, Installation, cont’d – Extron Electronics MAV Plus series Large Scale Setup Guide User Manual

Page 9

Advertising
background image

CrossPoint / MAV Matrix Switchers • Installation

Installation, cont’d

2-4

CrossPoint / MAV Matrix Switchers • Installation

2-5

Refer also to the CrossPoint 450 Plus / MAV Plus User’s Manual at

www.extron.com

.

Refer also to the CrossPoint 450 Plus / MAV Plus User’s Manual at

www.extron.com

.

e

Audio inputs (audio BMEs) — Connect stereo or mono audio

sources to the 5-pole or 3-pole captive screw connectors.

L

R

Unbalanced Stereo Input

Balanced Stereo Input

Ring

Sleeve (s)

Tip

Sleeve

Tip

Sleeve

Balanced Mono Input

Tip

Tip

Ring

Ring

Sleeves

Tip

Do not tin the wires!

f

Audio outputs (audio BMEs) — Connect stereo or mono audio

devices to the 5-pole or 3-pole captive screw connectors.

CAUTION

For unbalanced stereo audio, connect the

sleeve(s) to the ground contact. DO NOT
connect the sleeve(s) to the negative (-) contacts.

Unbalanced Stereo Output

Balanced Stereo Output

L

R

Ring

Tip

Sleeve(s)

Tip

Ring

Sleeve(s)

Tip

Tip

NO GROUND HERE.

NO GROUND HERE.

Balanced Mono Output

Ring

Sleeves

Tip

Do not tin the wires!

Remote control connections

g

Remote port

If desired, connect a control system or computer

to the rear panel Remote RS-232/RS-422 port.

N

Remote port defaults: RS-232, 9600 baud, no parity, 8-bit,

1 stop bit, no flow control.

RS-232 Function

Pin

Function

1
2
3
4
5
6
7
8
9

TX

RX

Gnd




Not used
Transmit
Receive
Not used
Ground
Not used
Not used
Not used
Not used

TX–

RX–

Gnd

RX+

TX+

Not used
Transmit (–)
Receive (–)
Not used
Ground
Not used
Receive (+)
Transmit (+)
Not used

RS-422

5

1

9

6

h

LAN port — If desired, connect a network WAN or LAN hub, a

control system, or computer to the Ethernet RJ-45 port.

Network connection

— Wire as a patch (straight) cable.

Computer or control system connection

— Wire the

interface cable as a crossover cable.

N

The factory default IP address is 192.168.254.254.

BME connection and selection

N

BME 0 should house the front panel controller (if included

in your system) and be the BME used for system control

and monitoring via the serial and Ethernet LAN ports.

i

BME address switch — Each BME must be set to a unique

address of 0 through 5 (addresses 6 through 9 are invalid).

LAN

ACT LINK

RESET

REMOTE

Rx

Tx

Rx

Tx

BME COMM

IN

OUT

Rx

Tx

4

-

+

BME

ADDRESS

9

8

7

10

Tx

Rx

4

Sync BMEs cannot be set to address 0.

The addresses used in the system must be sequential with no

skipped numbers.

j

BME COMM interconnect ports —

The BMEs in multiple BME

systems must be daisy-chained.

Connect an RJ-45 cable from BME 0’s BME Comm Out connector

to the nearest BME’s BME Comm In connector (usually BME 1).

LAN

ACT LINK

RESET

REMOTE

Rx

Tx

Rx

Tx

4

-

+

BME COMM

IN

OUT

BME

ADDRESS

Rx

Tx

9

BME COMM

OUT

IN

From Previous BME

To Next BME

8

7

10

Connect the next RJ-45 cable from BME 1's BME Comm Out

connector to the nearest unconnected BME’s BME Comm In

connector (usually BME 2).

Continue connecting RJ-45 cables from each daisy-chained

module’s BME Comm Out connector to the next module’s BME

Comm In connector until all modules are included in the chain.

Advertising
This manual is related to the following products: