ENGLISH

• Plug the machine into the power socket and the red LED on

the electronic control panel will flash.

• To P

OWER

U

P

THE

M

ACHINE

, press and release the red

button Fig. 9

• To E

NERGISE

THE

M

AGNET

, press and release the yellow

button - the yellow LED will light Fig. 10 .

RECHECK the pilot is still centred on the hole position -

energising the magnet can sometimes cause the unit to move

slightly from the centre mark, reposition if necessary.

• The magnet will hold on all ferrous materials from a

minimum of 6mm (1/4”) thickness.

STARTING THE CUT

ALWAYS

lower the safety guard.

• S

TART

THE

MOTOR

by pressing and releasing the green button

- the green LED will light Fig. 11 .

• Wind the cutter gently down to the surface of the work

and apply light pressure until the cutter has made the initial

groove in the surface. Increase the pressure until the motor

is loaded Fig. 12.

• Maintain steady pressure throughout the rest of the cut.

Too much pressure will not speed the cut, it will reduce the

life of the cutter and may cause damage to the motor. If the

shavings become blue add more oil.

TO STOP THE MOTOR,

PRESS

&

RELEASE

GREEN

BUTTON

.

• If the cutter jams in the workpiece,

STOP

THE

MOTOR

and gently

raise the cutter out of the workpiece before re-starting.

• If the power is interrupted during the cut, the machine must

be reset before the motor will restart.

• At the end of the cut, the slug will be ejected. Withdraw the

cutter from the work piece and stop the motor.

• To disengage the magnet, press and release the yellow button

- the magnet will not disengage immediately, there will be a

3 second delay before the magnet disengages along with a

continuous beep.

Incorrect start up or shut down sequence:-

• A single beep will be heard for all operations carried out in

the correct sequence. A continuous beep will sound for any

incorrect sequence.

• Neither drill nor magnet can be operated until red power

button is activated.

• When the red power button is activated, the motor will not

run until the magnet is activated.

STARTING THE CUT

(E

LECTRONIC

PANEL

)

N.B. Safety strap and guards have been omitted from the photo’s.

Fig. 9

Fig. 10

Fig. 11

Fig. 12