MAGNETIC DRILL SAFETY INSTRUCTIONS

• Always inspect the whole unit before use.

• Regular maintenance is essential - check

nuts, screws etc. for tightness before each

use.

• Check cable and plug for damage.

• Never use blunt or damaged cutters.

• Never use a larger diameter cutter than

specified for the machine

• Always use the safety guards (where

fitted).

• Always wear goggles and gloves

• Secure the unit with the safety strap before

drilling.

• Always disconnect from the power source

before changing cutters or working on the

machine.

• Remove rings, watches, ties etc. that could

tangle in the moving parts.

• Occasionally apply a few drops of oil to

the rack toothing.

The bearings of the feed shaft are self-

lubricating and must not be greased

• Grease the sliding surface of the carriage

with MOLYCOTE grease.

• When not in use or being transported the

unit should be kept in the case supplied.

• After use ensure unit is clean of swarf and

dirt.

• Parts that are worn or damaged should

be replaced immediatley with genuine

manufacturer’s replacements.

• Ensure all cutting edges are sharp when

in operation. Using blunt cutting tools may

lead to an overload of the motor.

• After every 30 minutes running, it is

recommended that the machine is laid on

its side to permit grease to run across the

gear train.

• Keep the unit and workpiece as clear of dirt

and shavings as possible.

• On swivel machines, ensure that the swivel

base is locked in the required position.

• Do not attempt to change speed while the

drill is running.

• Only use accessories recommended by the

manufacturer.

• Never modify the tool in any way.

MAINTENANCE INSTRUCTIONS

• After repeated use, the cradle may

become loose. This is remedied by adjusting

the tension screws on the side of the body.

Put 2.5mm Allen Key into head of cradle

retaining nuts, using 8mm Spanner undo the

locking nuts anti-clockwise, holding the

Allen key without moving grub screws.

Using the Allen Key gently tighten screws

in series until the cradle moves freely in

the slide but does not allow the motor to

wobble.

When adjustment is complete re-tighten

locking nuts clockwise, ensuring the

grub screws do not move from their new

positions.

ENGLISH

IMPORTANT MESSAGE

TO PREVENT DAMAGE TO THE CIRCUITRY,
NEVER USE ELECTROMAGNETIC DRILLING
MACHINES AND WELDING EQUIPMENT ON
THE SAME MATERIAL SIMULTANEOUSLY