Receiving and Inspection Instructions

• Check the bill of lading to verify receipt of all listed items (including any loose accessory items). Notify the carrier and

the local ANEMOSTAT representative of any shortages or items shipped in error.

• Thoroughly examine all units for transportation damage (dents, punctures, etc). If damage is found, immediately

notify and file a claim with the carrier. Note details of any damage on the bill of lading before signing for the
shipment.

• Each terminal has a nameplate indicating the model number. When requested, the unit may also be mark with job-

specific information (tagging). Locate the nameplate and verify that the correct units with options (controls, heating
coils, etc) where received as ordered.

• Store units in a secure, dry location in the original packing, and do not stack any higher than as shipped.

Warning – Electrical Shock, Burn, and other Hazards

• Heating elements must be disconnected, or water coils allowed to cool prior to servicing. Electric heaters may start

automatically, or water valves may open intermittently. It is essential to disconnect all power and control circuits
prior to servicing to avoid burning hazards.

• All fastening straps or hangers must mechanically lock the terminal in place and withstand typical vibration and/or

disturbances during use.

• Use caution during rigging such that all equipment remains adequately secured until it is affixed and secured in its

final location.

• All supports must be designed to meet applicable local codes and ordinances. Before rigging and installation, check

equipment weights such to ensure temporary and permanent supports are safely maintained.

• Make certain all power sources are disconnected prior to installation or servicing this equipment. Make certain if

there are multiple power connections, that all are securely disconnected to avoid electrocution or shock injuries.

• Disconnect control circuits or pneumatic control systems to avoid injury when working on dampers or actuators,

which may respond automatically to a remote control source.

• Guard against flame hazards when soldering or brazing water coil connections to avoid personal injury or property

damage. Prior to using any open flame, keep a fire extinguisher nearby.

• All insulated units (except closed-cell) contain fiberglass wool. Disturbing the insulation could expose the installer to

airborne particles of glass wool fibers and ceramic fibers. Certain jurisdictions feel that exposure to these fibers
through inhalation can cause cancer. Glass wool fibers may also cause respiratory, skin or eye irritation.