A

Z ≥ 2 *Z

min

Input

Ground

Lift

Input Ground Lift in position:
grounded

LINK B

Input

Channel B

3



2

2

3





3

2

2

3



To

Channel B

To

Channel A

Input

Channel A

LINK A

ALWAYS SWITCH OFF THE AMPLIFIER

BEFORE CHANGING MODES

3 INST

ALL

ATION

USER MANUAL
D - P O W E R S E R I E S

P. 4

D - P O W E R

S E R I E S

3.6.3 Mono-Bridge Operation

One-channel mono bridged operation.

The second amplifier channel processes the same input signal, but with reversed
phase. The (single) load is connected between the two positive channel outputs
using a suitable connected SPEAKON connector. While the total output of the
amplifier remains the same, both the available output voltage and the minimum
impedance that can be connected are doubled, as compared with stereo ope-
ration. Only channel A-Input is active. A signal feeding channel B will have no
effect on the output. Turn the volume of channel B down to zero.

WARNING !
In Mono-Bridge mode RMS output voltages are as high as 230 V. Wiring to
the speaker loads must conform to NEC Class 3 safety standards or its equi-
valent that meets all national and local electric codes.
All customer specific cables may only be manufactured by qualified suppli-
ers/personnel. All cabling or rewiring work must be carried out by qualified
personnel.

* Z

min

= 4 Ω for D-POWER 2, 3 and 4

3.7 Wiring
3.7. XLR Connection

XLR: Pin  = Ground (or lifted via 5 Ω resistor) (See 3.5 Ground Lift)

Pin 2 = Hot (inphase)

Pin 3 = Cold (out of phase)

Always use symmetrical (balanced) shielded cable to connect the amplifier.