CASTLE, INC

TSM-35 OWNERS MANUAL V1.2

Page 20 of 33

retract, and the clamp does not release. In this situation you may need to readjust the Drill Stop

Switch.

Fig 10

1.

Turn off Air and Electrical power to the machine and raise the Case Top to its fully
opened position.

2.

Under the red drill, you will find two cylinders. The cylinder on the left is the cylinder
which drives the Drill Carriage.

3.

On the Drill Carriage Cylinder there is a magnetic reed switch with a tensioning screw.
Use a Phillips screw driver to loosen the screw so that the switch can move freely.

4.

Open the door on the Control Box after you are sure that electrical power and air have
been shut off to the machine.

5.

Use a continuity tester and touch it to pins 9 and 10 on the Control Board Terminal Strip.
You might read a few kilo Ohms of resistance.

6.

Once touching 9 and 10, pull the Drill Carriage forward until it is approximately

1

/

16

inch

away from the end of the stroke and hold in place.

7.

Slide the Drill Stop Switch until you read NO RESISTANCE and tighten the tensioning
screw.

Note: Over tightening this screw may cause the switch to fail.