7 Service and Maintenance

Warning:

Electrical hazard: Do not attempt to service Control Box components. Contact Castle,

Inc. for the proper service information.

7.1 General

To ensure productivity and longevity for your Castle Screw Pocket Machine, it is essential to

follow a few simple steps. How often these steps are performed depends upon the number of

hours the machine is operated each day. As a general rule, operators should visually inspect

the machine at the start of each work shift in the following manner:

Check oil level in the drill lubricator.

Check power cord and Foot Switch cord for wear or damage.

Check spindle bearings for rough or noisy operation

Ensure that the router bit and the drill bit are clean, sharp and undamaged.

Check belt for wear or damage.

Keep the router and drill motors free from dust build up.

Check for proper Safety Switch function. Turn the machine on and press the Foot

Switch without a work piece against the Safety Buttons. If the Safety Switch is working

properly the machine should not cycle. If you suspect a Safety Switch malfunction,

contact Castle, Inc. at 800.282.8338 as soon as possible for corrective action.

It is recommended that periodically (at least once per 40 hours of operation) you blow

out all upper areas of your model TSM-35 by turning off the power supply and lifting the

Case Top to its fully open position. Blow out the compartment with approximately 30 PSI

compressed air. Pay particular attention to keeping the Interlock Safety Switch free of

sawdust.

Caution:

Always wear safety goggles when using compressed air.