6HFXULW\&RGHV $XWKRULW\/HYHOV

&RQW

7RDVVLJQ8VHU&RGHVDQG$WWULEXWHV

The following lists the various command strings for adding user codes and attributes.
Refer to the User Setup chart at the back of this manual for factory assignments of user

attributes and to keep a record of user programming.

NOTE: Partition Programmer code can be used only for user numbers assigned to that

programmer’s partition.

Add User Code:

Master/Part. Prog.code + [8] + user no.

+

new user’s code

(

Users 03/33 are preset

User 01 = installer

User 03 = partition 1 programmer

to partition programmers,

User 02 = master

User 33 = partition 2 programmer

but can be changed.)

The Touchpad beeps once to confirm that new user was added.

Delete User Code:

Master/Part. Prog. code + [8] + [user no.] + [#] [0]

The user code and all attributes* programmed for this user number,
including any associated RF keys, are erased from the system.
(*except assigned partition)

Authority Level:

Master/Part. Prog. code + [8] + [user no.] + [#] [1]+ auth. level

Authority Levels (see definitions on previous page):
0 = standard user

3 = duress

1 = arm only

4 = partition programmer

2 = guest

Access Group:

Master/Part. Prog. Code + [8] + [user no.] + [#] [2]+ group (1-8)

You can assign users to a group, then set an access schedule that
defines the times this group of users can operate the system. The
system ignores these users outside the scheduled times.

User’s Partition:

Master Code + [8] + [user no.] + [#] [3]+ partition(s) + [#]

(to end)

Factory Assignments:

Use this command to assign the partitions the user can access. Enter

Part. 1 = users 03-32

partition numbers sequentially, then press [#] to end the entry.

Part. 2 = users 33-49

Users can operate any combination of partitions desired.
Partition Numbers:
0 = clears part. 1 and part. 2 assignments

2 = partition 2

1 = partition 1

3 = common partition

RF User Number:

Master/Part. Prog. Code + [8] + [user no.] + [#] [4]+ zone no.

Use this command to assign a wireless button device (keyfob) to this
user (keyfob must be enrolled in system first; see installer).

Z

one number: enter the zone number assigned to a button on the

keyfob that will be used for arming/disarming by this user.

Pager On/Off:

Master/Part. Prog. Code + [8] + [user no.] + [#] [5] + 0 or 1

You can program a user so that a message is sent to a pager
whenever this code is used to arm or disarm the system.
Paging On/Off: 1 = allow paging; 0 = no paging for this user