6xppdu\ri$xgleoh9lvxdo1rwlilfdwlrqv, Xvwrp(qjolvk'lvsod\7rxfksdgv – ADT Security Services 3000 User Manual

Page 47

Advertising
background image

– 47 –

6XPPDU\RI$XGLEOH9LVXDO1RWLILFDWLRQV

&XVWRP(QJOLVK'LVSOD\7RXFKSDGV

SOUND

CAUSE

DISPLAY

LOUD,
INTERRUPTED*
Touchpad & Ext.

FIRE ALARM.

FIRE

is displayed; descriptor of zone in alarm is

displayed. If a fire alarm is manually activated, zone
number 95 will be displayed.

LOUD,
CONTINUOUS*
Touchpad & Ext.

BURGLARY/AUDIBLE
EMERGENCY ALARM.

ALARM

is

displayed. If programmed, descriptor of

zone in alarm is also displayed

ONE SHORT BEEP
(not repeated)
Touchpad only

a. SYSTEM DISARM.

b. SYSTEM ARMING ATTEMPT
WITH AN OPEN ZONE.

c. BYPASS VERIFY.

a. DISARMED/READY TO ARM is displayed.

b. Number and descriptor of open protection zone is
displayed.

c. Numbers and descriptors of the bypassed zones
are displayed (One beep is heard for each
zone displayed). Subsequently, the following is
displayed: DISARMED BYPASS /Ready to Arm.

ONE SHORT BEEP
(once every 40 secs)
Touchpad only

a. SYSTEM IS IN TEST MODE.

b, LOW BATTERY AT A
TRANSMITTER.

a. Opened Zone identifications will appear.

b. LO BAT displayed with description of transmitter.

TWO

SHORT BEEPS

Touchpad only

ARM AWAY.

ARMED AWAY displayed. Red ARMED indicator
lit.

THREE SHORT
BEEPS
Touchpad only

a. ARM STAY, NIGHT-STAY,
OR INSTANT.

b. ZONE OPENED WHILE
SYSTEM IS DISARMED.

a.

ARMED STAY or ARMED INSTANT displayed.
Red ARMED indicator lit.

b. CHIME displayed, descriptor of open protection
zone will be displayed if the [✱] key is pressed.

RAPID BEEPING
Touchpad only

a.

TROUBLE.

b. MEMORY OF ALARM.

c. SYSTEM LOW BATTERY.
d. EXT. SOUNDER WIRE FAIL.

a.

CHECK

displayed. Descriptor of troubled

protection zone is displayed.

b.

FIRE or ALARM is displayed; descriptor of zone

in alarm is displayed.

c. SYSTEM LO BAT displayed.

d.

BELL FAILURE is displayed.

SLOW BEEPING
Touchpad only

a. EXIT DELAY WARNING
(if programmed).

b. ENTRY DELAY WARNING.

a. ARMED AWAY is displayed along with You May
Exit Now.

b. DISARM SYSTEM OR ALARM WILL OCCUR
is displayed. Exceeding the delay time without
disarming causes an alarm.

* If a bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady

ring.

Advertising