2 - measurement result, 3 - recalculation of the unbalance values – CEMB USA K8 (B) User Manual

Page 11

Advertising
background image

I 0457 -

11

8a

8b

cm

60 mm

GB

5.2 - Measurement result

Inside correction

Outside correction

After performing a balancing spin, the amounts of unbalance are shown on the digital readouts.
The illuminated LEDs 3 and 4 indicate the correct angular position of the wheel to mount the counterweights (12
o’clock).

If the unbalance is less than the threshold value selected,

is displayed instead of the unbalance value; with

the values below the threshold can be read, selected gram by gram.

Note : in the case of wheels with a diameter less than or equal to 13” and at temperature conditions near 0°, the wheel

balancer automatically inserts a special measuring cycle composed of two successive measurements.

The accuracy of the unbalance values and the reliability of the wheel balancer remain unchanged. This type of
operation is reset each time the wheel balancer is started.

5.3 - Recalculation of the unbalance values

Press

after new setting of the measurement.

d) Setting with gauge extension

Extension + 60

The extension increases the gauge distance measurement field by 60 mm (Fig. A) and allows distance
measurement even when the rim has a special profile (Fig. B).
Proceed as indicated below:
- Fit the extension on the distance gauge.
- Measure the distance as already described.
- Having read value “a” on the dial, reset the gauge to 0 and set by hand the value “a + 60”
- Manually set the diameter and the width.

A

B

Advertising