4 - technical data, 2 - handling and lifting, 3 - startup – CEMB USA K8 (B) User Manual

Page 4: 1 - anchoring, 2 - electrical connection

Advertising
background image

I 0457 -

4

2

2a

GB

1.4 - Technical data

Single-phase power supply

115 / 230 V - 50/60 Hz

Protection class

IP 54

Max. power absorbed

0,8 Kw

Balancing speed

< 100 min

-1

Cycle time for average wheel (14 kg)

6-8 seconds

Max. resolution of measurement

1 gram

Position resolution

± 1.4 °

Average noise

< 70dB (A)

Rim-machine distance

0 - 252

mm

Rim width setting range

1.5” - 20” or 40 - 510 mm

Diameter setting range

10” - 30” or 265 - 765 mm

2 - Handling and lifting

Note: DO NOT LIFT THE WHEEL BALANCER USING OTHER GRIPS.

3 - Startup

3.1 - Anchoring

The machine can operate on any fl at non resilient fl oor.
Make sure that the machine rests solely on the three support points provided (Fig.2a).

It is advisable to secure the system to the ground using the specifi c feet (Fig. 2a). if the machine is

continually used with wheels weighing over 35 kg.

3.2 - Electrical connection

The machine is supplied with a single-phase mains cable plus earth (ground).
The power supply voltage (and mains frequency) is indicated on the machine identifi cation plate and cannot be
changed. Connection to the mains must always be made by expert personnel.
The machine must not be set up without proper earthing.
Connection to the mains should be through a slow acting safety switch rated at 3 A (230V) or 8 A(115 V).
See enclosed diagram.