1 - inconsistent unbalance readings, 1 - replacing the protection fuses – CEMB USA K8 (B) User Manual

Page 16

Advertising
background image

I 0457 -

16

GB

7.1 - Inconsistent unbalance readings

It may occur that after balancing a wheel, when removing it from the wheel balancer and then remounting it, the
wheel is not balanced.
This is not the result of an incorrect indication by the machine, but only of incorrect mounting of the wheel on the
flange, i.e. in the two mountings the wheel has assumed a different position with respect to shaft axis of the wheel
balancer. If the wheel has been mounted on the flange with screws, it may be that the screws have not been tight-
ened correctly in gradual criss-cross manner one after the other, or (as often occurs) holes have been drilled in the
wheel with too wide tolerances.
Small errors, up to 10 grams (0.4 oz), are to be considered normal in wheels locked with a cone: the error is normally
greater for wheels locked with screws or studs.
If, after balancing, the wheel is still unbalanced when refitted on the vehicle, this could be due to the unbalance of
the brake drum or very often is due to the screw holes in the rim and the drum drilled with too wide tolerances. In this
case a readjustment would be advisable using the wheel balancer with the wheel mounted.

8 - Routine maintenance

Before carrying out any operation on the machine, cut the power supply to the machine.

8.1 - Replacing the protection fuses

A protection fuse is fitted on the power board, accessible by dismantling the weight shelf (see Exploded Drawings). If
fuses require replacement, use ones with an identical current rating.
If the fault persists, contact Technical Service.

NONE OF THE OTHER MACHINE PARTS REQUIRE MAINTENANCE.

Err.32/

Err.33/

Err.34/

Err.35/

Err.36/

Err.37

Errors related to test functions of the wheel

balancer.

1. Cancel the error and continue using the wheel balancer as normal.

Advertising