6 - Set-up

6.1 - Autodiagnostics

Performs tests useful for maintenance staff.

6.2 - Autocalibration

For autocalibration proceed as follows:
- Fit a wheel with steel rim of average dimensions on the shaft. Example 6” x 14” (± 1”)
- Set the exact dimensions of the wheel mounted.

CAUTION !!

Setting incorrect dimensions will result in the machine not being properly calibrated and hence all

the subsequent measurements will be incorrect until a new autocalibration is performed with the

correct dimensions!!

- Perform a spin under normal conditions.

- Add a 60 g. sample weight (2.00 oz) on the outside in any angular position.

- Shift the sample weight from the outside to the inside keeping the same

angular position.

- Turn the wheel until the sample weight is in the 12 o’clock position.

END OF AUTOCALIBRATION

CANCEL AUTOCALIBRATION IN ANY PHASE.