Vibrometer function

5 - 1

Chapter 5

Vibrometer function





One of the simplest, but at the same time most important, values in vibration analysis is the
overall value of the vibration itself. This is often the first parameter to consider when
assessing the operation of a motor, fan, pump, machine tool, etc.
Suitable tables are used to discriminate between an excellent condition or a good,
acceptable, tolerable, unacceptable or even dangerous condition. (see Appendix B –
Judgement criteria
).
In some cases it may be interesting to know the synchronous vibration modulus and phase
values, that is to say corresponding to the rotating body’s rotation velocity (1xRPM), or its
multiples (2xRPM, 3xRPM, 4xRPM, 5xRPM).
The vibrometer function can be used to take this type of measurement easily and
intuitively, saving the results in a special record.


Measurement settings

The settings used to measure vibration are all displayed in the Vibrometer page and can be
adjusted by pressing the key: for greater clarity all measurement results are hidden,
with only adjustable parameters remaining visible.
The parameter that can be changed is displayed in negative, by pressing the

and the

arrows you can scroll through all of the values that can be selected. With the

and keys, you can move to the previous or next parameter.


1. Sensor type:

One of the sensors for which the sensitivity has been set must be selected (see 4.1
Sensor sensitivity
):

ACC-1 : type 1 accelerometer (powered – IEPE type)

ACC-2 : type 2 accelerometer (powered – IEPE type)

VEL-1 : type 1 velocimeter (not powered)

VEL-2 : type 2 velocimeter (not powered)