Vibrometer function

Synchronous measurement:





1. sensor connected
2. order of the harmonic measured

1xRPM = fundamental harmonic (synchronous with the rotation velocity)

2xRPM = second harmonic (frequency double the rotation velocity)

3xRPM = third harmonic (frequency triple the rotation velocity)

4xRPM = fourth harmonic (frequency four times the rotation velocity)

5xRPM = fifth harmonic (frequency five times the rotation velocity)

3. filter width
4. vibration modulus, with unit and type
5. vibration phase expressed in degrees (0°÷359°)
6. frequency of the harmonic measured; it coincides with the rotation velocity in the

event of a 1xRPM measurement, otherwise it is respectively double, triple, etc.


The measurement can be started and stopped by pressing

























5

3



4


6