Setting device number and parameters (device mode), Zone switch settings – Contemporary Research ICC1-IR IR User Manual

Page 9

Advertising
background image

Contemporary Research

9

ICC1-IR

Installation

Setting Device Number and Parameters (Device Mode)

Turn enclosure so the DIP switches are on the bottom

In the next step, you’ll need to set up the device number and operation parameters for the ICC1-IR. Notice that

the functions of the S1 and S2 switches change when you set the unit in Device mode.

1. Make sure S2 Switch 6 is OFF (unit in Device mode).

2. Set the Device number by turning on the switches that add up to the desired device number. For

example, for Device #259, turn on S1 switches 1 and 2 (3), S2 switch 1 (256)


Zone Switch Settings (S2

– right side)


To define the controller’s Zone, use the following pattern of switches ON for the S2 DIP.

Zone

Value

1

2

3

4

256

512

1024 2048

1

256

X

2

512

X

3

768

X

X

4

1024

X

5

1280

X

X

6

1536

X

X

7

1792

X

X

X

8

2048

X

9

2304

X

X

10

2560

X

X

11

2816

X

X

X

12

3072

X

X

13

3328

X

X

X

14

3584

X

X

X

15

3840

X

X

X

X