Leak Testing
All components of gas supply system,
including manual shut off valves and the
piping in the interior of the unit, should be
leak tested with a soap solution before
operating the appliance and at least on an
annual basis thereafter.
































All gas fired heat exchangers are completely
tested at the factory before shipment. This
will remove nearly all of the oils that have
been used in the manufacturing process.
However, trace amounts may remain. When
performing the initial startup at the jobsite, it
is highly recommended that people or any

other living animals, which may be sensitive
to the residual odors or gases, NOT be
present in the conditioned space during the
startup. In all cases, including the initial
factory firing and testing, any of the gases
will be under the acceptable level of
concentration for human occupancy.










Refrigerant-to-Water Heat Exchanger
Condenser water pump, condenser water
piping, cooling tower or geothermal loop,
pressure gauges, strainers, piping insulation
and all components of the waterside piping
must be field installed.

Open Loop Applications
This product contains one or more
refrigerant-to-water heat exchangers made
of copper, which is subject to corrosion and
failure when exposed to chlorides.











Do not allow water containing any form of
chlorides to enter this heat exchanger.




Do not use open flame or other
source of ignition for leak testing. Fire
or explosion could result causing
property damage, personal injury, or
death.

DANGER


LEAK CHECK GAS PIPE

The gas pipe in the unit should be
checked for leaks before startup.
Leak checking is the responsibility of
the

installing

contractor.

All

connections should be checked for
leaks

annually

after

installation.

Failure to leak check could result in
fire, explosion, or other hazardous
situations.

DANGER


Some soaps used for leak detection
can be corrosive to certain metals.
Rinse piping thoroughly after leak
test has been completed.

CAUTION


Those sensitive to odors or gases
from trace amounts of residual oils
should NOT be present in the
conditioned space during the startup
of a gas fired installation.

WARNING


OPEN LOOP APPLICATIONS


Failure of the condenser as a result
of chemical corrosion is excluded
from coverage under AAON Inc.
warranties and the heat exchanger
manufacturer’s warranties.