Statframesdelivered / statpacketsreceived = 0, Statframesdropped ≠ 0, Statframesdelivered is increasing but black image – ALLIED Vision Technologies Bigeye G-1100 Cool User Manual

Page 49

Advertising
background image

AVT GigE Cameras Installation Manual V1.0.0

49

Troubleshooting

Is the camera listed in Viewer but can't acquire images?

Reset your camera settings to factory default.

VIMBA Viewer

In controller window, set UserSetDefaultSelector = Default, and click the
UserSetLoad button.

GigE Sample Viewer

In controls window, set ConfigFileIndex = Factory, click ConfigFileLoad button.
While streaming, check the camera Stats.

StatFramesDelivered / StatPacketsReceived = 0

Likely a firewall is blocking incoming
traffic. Disable your firewall on Ether-
net adapter connected to camera.
Ensure that:
For VIMBA Viewer:

TriggerSelector = FrameStart
TriggerSource = Freerun or FixedRate

For GigE Sample Viewer:

FrameStartTriggerMode = Freerun or
FixedRate.

Other trigger modes require a trigger
event to capture frames.

StatFramesDropped ≠ 0

Packets are incoming, but all dropping.
Be sure you have jumbo frames enabled
on your adapter, see

Ethernet adapter

optimization

on page 19. Alternatively,

reduce camera packet size value to
1500 using the viewer.

StatFramesDelivered is increasing but black image

Be sure your scene is sufficiently lit.

Increase exposure value.
For VIMBA Viewer: ExposureTimeAbs
For GigE Sample Viewer: ExposureValue

Ensure the camera lens is properly installed and the lens cap has been
removed.

Note

If you are still having problems, email to

[email protected]

.