Programming, Channel setting commands, Device assignment – AMX AXB-TM5 User Manual

Page 13

Advertising
background image

Programming

9

AXB-TM5 Television Manager

Programming

You can program the AXB-TM5 to perform a wide variety of operations using Axcess

Send_Commands. This section describes channel settings, IR functions, and system

Send_Commands. Refer to the AXCESS Programming Guide for additional programming

information.

Channel Setting Commands

The AXB-TM5 use the channel setting commands listed in the following table.

Device Assignment

The device assignment must be the same as the device number set on the Device DIP switches

(FIG. 2 on page 3).

AXB-TM5 Channel Settings

Channel

Function

1

Generates IR/Serial functions 1, else Off

2 - 127

Channels the generate IR code for the corresponding functions

128 - 247

Push and release channels for received IR code

248

A push on this channel indicates a power failure error

249

Response LED blinks when channels 249 and 250 are On

250

Response LED lights when channel is On

251

I/O is On (switch to GND) when channel is On

252

I/O 2 is On (switch to GND) when channel is On

253

I/O 3 is On (switch to GND) when channel is On

254

I/O 4 is On (switch to GND) when channel is On

255

Channel is On if the TV Power Sensor detects a horizontal scan frequency

Turning a channel (IR/Serial function) on while another one is currently on will
automatically turn the current one off first. Contact closure inputs on I/O 1 through I/O
4 will also generate PUSHes and RELEASEs on channels 251 through 254,
respectively.