RED-1 INstAllAtION

Connect the wire according to the color code silkscreened as text next to the IDC or as shown on the label on the back enclosure
(see figure below). The color code uses the T568A standard for wiring. When using the T568B wiring scheme, please note that the orange
wire pair (OR and WH/OR) and green wire pair (GR and WH/GR) need to be swapped. After inserting the wires, press the tabs until the
insulation is punctured with an audible click. No wire stripping is necessary.

Figure X: IDC wiring scheme

Note the appropriate bend radius requirements for category cables as shown in the figure below.

Software support in Audia configuration software Version 5.1 and Nexia Version 3.1 or later provides user programming of all remote
functions, network setup, device naming, and device maintenance.