Biamp RED-1 User Manual

Page 7

Advertising
background image

7

RED-1 sEt Up

Edit Device ID
To name the unit, scroll to the ID Tag icon and press the Select button. Use the scroll wheel and Select button to choose the desired
characters. The Device ID must match that of a corresponding block in the Audia or Nexia design. More than one unit may be identified
with the same design block (same ID). Device IDs may also be assigned via Device Maintenance in the Audia or Nexia software.

Edit Network Configuration
To edit the network configuration, scroll to the Network icon and press the Select button. The default setting (Static) initializes the
IP address to 192.168.1.201, network mask to 255.255.255.0, and gateway to 0.0.0.0. These default settings allow RED-1 to be discovered
by an Audia or Nexia device that also has default settings. Network settings may also be assigned via Device Maintenance in the Audia
or Nexia software.

Edit Lock Code
To set password protection, scroll to the Key icon and press the Select button. Use the scroll wheel and Select button to choose the desired
characters. During normal operation, holding down the Select button for two seconds will lock the unit, and the user will be prompted for
the Lock Code before obtaining access. Lock Codes may also be assigned via Device Maintenance in the Audia or Nexia software.

Advertising
This manual is related to the following products: