Technical Data

8.5.

electrical data

Connections

2 cable glands (M20 x 1.5) with screw-type terminals 0.14 – 1.5 mm

2

or

circular plug-in connector (M12, 8 pole plug)

Interfaces

Communications interface USB:
Direct connection to PC via USB adapter.
Communication with communications software based on FDT/DTM
technology.
An external adapter with integrated interface driver is required.
(see chapter “17. Accessories”)

Supply voltage

24 V DC ± 10% max. residual ripple 10%

Power consumption

< 3.5 W

Input resistance

for set-point value signal

180 Ω in 0/4 – 20 mA / Resolution 12 bit

Protection class

3 in accordance with VDE 0580

Analog position feedback

max. Burden (load)
for current output 0/4 – 20 mA)

560 Ω

Inductive proximity switches

100 mA current limit

Binary input

Not galvanically isolated

0 – 5 V = log “0”, 10 – 30 V = log “1”
inverted input in reverse order
(input current < 6 mA)

8.5.1.

electrical data with as-interface bus control
(optional)

Connections

circular plug-in connector (M12, 4 pole plug)

Supply voltage

29.5 V – 31.6 V DC (according to specification)

Units without external supply voltage:

Max. power consumption

150 mA

Units with external supply voltage:

External supply voltage

24 V ± 10 %

The supply voltage unit must

feature a secure disconnection in
accordance with IEC 364-4-41
(PELV or SELV)

Max. power consumption

100 mA

Max. power consumption

from AS-Interface

50 mA

english