START STOP BATCH

START: it is possible activate the start of batch in two different way:

1. from remote input: assigning the functions of start/stop batch to the input 1 (POS.

5.9) or input 2 (POS. 5.10) and using the input/s like visualized from page 12.

2. from keyboard: short pressing of the key

N.B.: the start of batch from keyboard is always on the descent front (release of the

key) and is not available with the function of batch consent (POS. 12.7)

STOP: the stop of batch can be due to three events:

1. keyboard or remote input (manual stop): short pressing of the key

2. end of batch: in this case the stop of batch will have activated from a output signal to

the attainment of the batch quantity

3. maximum time of batch: if a maximum batch time has been set and this is exceeded,

the batch in progress is stopped independently from the batched quantity


Notes:

q during the batch the symbol of the active batch and the name of the formula are

visualized on video.


q When the batch outputs are enable, pushing for more of 5 sec. the key , the outputs

will remain energized till the key is released. On the display, in place of the CT and ST
totalisers the following messages will appear:

!! VALVE !!
!! OPENED !!














IMPORTANT NOTES

The start of the batch disables any function listed below:


To optimize the performances of the meter used as a batch instrument, it is recommended to set it

as prompt as possible according to the plant requirements, choosing the opportune values of time

constant (pos. 3.1) and acceleration threshold (pos. 3.2).



POS 12.5

POS 12.6

POS 5.6

POS 12.1

POS 5.9

POS 3.7-5.8

POS 3.8

POS 5.7


* SE UTILIZZATO INGRESSO 1

** VALORE A ZERO

AUTO BATCH

BM AUTO SEL

BLOCK TOTALIZER

N. SAMPLES

INPU

T 1 ON START/STOP

BATCH

AUTO RANGE CHANGE OR

FROM INPUT

ENERGY SAVING

CALIBRATION

POS 12.5

AUTO BATCH

*DISABLE

POS 12.6

BM AUTO SEL

** DISABLE

POS 12.7

CONS. MODE

DISABLE

DISABLE

* DISABLE

POS 5.9

INPUT 1 ON START/STOP
BATCH

DISABLE

DISABLE

DISABLE

POS 5.10

INPUT 2 ON START/STOP
BATCH

DISABLE

DISABLE

DISABLE

DISABLE

POS 5.10

BM SELECT

DISABLE

** DISABLE

POS 6.1÷6.4

OUTPUT ON END BATCH

DISABLE

AGISCE SU