General data – Burkert Type 8035 User Manual

Page 12

Advertising
background image

95

88

88

180

91

21

75

114

105

104

Fig. 4: Dimensions in mm of the SE35 electronic module
Table 2: Height H in mm of SE35 electronic module associated to

an S030 fitting-sensor

DN (mm)

06

08

15

20

25

32

40

50

65

H (mm)

134 134 139 137 137 140 144 151 151

H

1)

The height H does not

depend on the type of con-
nection or on the material.

6.3.2. General data

Type

8025

8035

Pipe diameter

DN20 (except for DN specified
p.13) to DN400

DN6 to
DN65

Type of fitting

S020

S030

Fluid temperature

The fluid temperature may be restricted by the

fluid pressure and by the material of the fitting
used. See Fig. 5 et Fig. 6

Fluid pressure

The fluid pressure may be restricted by the fluid

temperature and by the material of the fitting
used. See Fig. 5 et Fig. 6

Flow rate measurement
• Measurement range
• Measurement error

with a teach-in

procedure (teach-in

function)

• Measurement error

with K factor of fitting

used

• Linearity
• Repeatability

• 0,2 to 10 m/s
• ±0,5 % of the full scale

• ± (0,5% of the full scale + 2,5 % of the

measured value) 1)

• ±0,5 % of the full scale 1)
• ±0,4 % of the measured value

Power supply

2 batteries of 9 V (6LR61)

Minimum autonomy: 1 year at 20° C

1)

Determined in the following reference conditions: fluid = water,

water and ambient temperatures = 20 °C, upstream and down-
stream distances respected, appropriate pipe dimensions.

10

Technicaldata

Type 8025/8035 battery powered

English

Advertising
This manual is related to the following products: