Available versions, Technical data, Conditions of use – Burkert Type 8035 User Manual

Page 9: Conformity to standards and directives

Advertising
background image

TOTAL :SE35/8035 COIL 9V

IP65

S/N 1439

00423921

W43MA

M

ade in Franc

e

1

2

4

5

7

8

3

6

Fig. 2: Name plate of the

8035

1.

Type of the device

2.

Specification of the flow sensor

3.

Power supply

4.

Manufacturing code

5.

Conformity logo

6.

Protection rating

7.

Serial number

8.

Order code

5.4.

Available versions

• The flowmeter-totalizer type 8035 is made up of an SE35 elec-

tronic module with order code 423921 and of an S030 fitting-
sensor which has to be ordered separately.

• The flowmeter-totalizer type 8025 exists in 2 versions:

type of flow sensor

seal material

order code

short, with coil

FKM

418403

long, with coil

FKM

418405

6.

TechnicAl DATA

6.1.

conditions of use

Ambient temperature

0 to +60 °C

Air humidity

< 80%, without condensation

Height above see
level

max. 2000 m

Protection rating

IP65, cover lid screwed tight and screwed
plugs.

6.2.

conformity to standards and
directives

The device conforms to the EC directives through the following
standards:
• EMC: EN 61000-6-2, EN 61000-6-3
• LVD: EN 61 010-1
• Vibration: EN 60068-2-6
• Shock: EN 60068-2-27
• Pressure: article 3§3 of the Pressure Directive 97/23/CE. Acc. to

the Pressure Directive 97/23/CE: the device can only be used in
the following cases (depending on the max. pressure, the DN of
the pipe and the fluid)

7

Technicaldata

Type 8025/8035 battery powered

English

Advertising