Installation of 8025 on the s020 fitting, Description of the electronic board connections, The s030 fitting-sensor – Burkert Type 8035 User Manual

Page 16

Advertising
background image

7.2.2. installation of 8025 on the s020

fitting

Insert nut 3 on the fitting 5.

Insert the snap ring 2 into the groove 4.

Check that seal 6 is correctly inserted on the

flow sensor.

Slowly insert the device 1 into the fitting.

If the mounting is correctly done the device cannot

turn around anymore.

Hand lock the assembly with the nut 3.

2

1

3
4
5

6

Fig. 7: Installation of 8025 on the S020 fitting

7.2.3. installation of the se35 electronic

module on the s030 fitting-sensor

Insert the electronic module 2 in the
S030 fitting-sensor.

Secure with a 30° clockwise rotation.

Tighten the lateral screw 3 to lock
the electronic module with the
fitting-sensor.

1

2

3

Fig. 8: Installation of the SE35 electronic module on the S030

fitting-sensor

7.3.

Description of the electronic
board connections

Terminal block:
+ : positive supply (red wire)
- : negative supply (black wire)

Connector : branchement du
capteur de débit

Terminal block

Connector

OFF ON

Fig. 9: Electronic board

connections

14

Installation

Type 8025/8035 battery powered

English

Advertising
This manual is related to the following products: